# Soft Story Retrofit Deadline in Santa Monica: 2026 Compliance Guide
The soft story retrofit deadline in Santa Monica represents one of the most aggressive mandatory seismic upgrade programs in Southern California. Building owners must understand their obligations, timelines, and engineering requirements to avoid penalties and protect tenants. This 2026 compliance guide covers every aspect of Santa Monica's soft story retrofit program.
What Is a Soft Story Building in Santa Monica?
A soft story building has a ground floor that is significantly weaker or more flexible than the floors above it. In Santa Monica, this condition commonly appears in multi-unit apartment buildings constructed before 1978 where the ground floor features:
- **Ground-floor commercial space** — Storefronts with large windows and open floor plans weaken the building's base
- **Minimal ground-floor walls** — Buildings with fewer shear walls on the first floor than upper floors
Santa Monica's building inventory contains hundreds of these vulnerable structures. The 1994 Northridge Earthquake demonstrated the catastrophic failure mode: upper floors pancake onto the weak ground floor, causing total building collapse and loss of life.
Santa Monica Soft Story Retrofit Timeline
Santa Monica enacted its Mandatory Seismic Retrofit Ordinance to address the inventory of vulnerable soft story buildings throughout the city. The program established a phased compliance schedule based on building characteristics.
Compliance Phases for Santa Monica
**Priority Buildings (16+ Units)** Larger apartment buildings in Santa Monica with 16 or more dwelling units faced the earliest compliance deadlines. These buildings house the most residents and present the greatest life-safety risk during a major earthquake.
**Standard Buildings (3-15 Units)** Mid-size multi-family buildings in Santa Monica with 3 to 15 units follow the standard compliance timeline. This category represents the largest number of affected buildings in the Santa Monica retrofit program.
**All Remaining Buildings** Any remaining soft story structures in Santa Monica that did not fall into earlier priority categories must comply under the final phase of the program.
Current Status in 2026
As of February 2026, Santa Monica has completed notification of all affected building owners. Property owners who have not yet begun the retrofit process face increasing enforcement pressure. The City of Santa Monica Building and Safety Division actively monitors compliance and issues violation notices for non-compliant properties.
Building owners in Santa Monica who have received a Notice of Non-Compliance must submit retrofit plans within the specified timeframe or face daily fines. The city does not grant extensions without documented engineering justification and an approved timeline.
Soft Story Retrofit Requirements in Santa Monica
Engineering Standards
Santa Monica requires soft story retrofits to meet the standards established in ASCE 41-17 (Seismic Evaluation and Retrofit of Existing Buildings) as adopted by the California Existing Building Code. Key requirements include:
**Performance Objective** — Buildings must achieve the Basic Performance Objective for Existing Buildings (BPOE), which targets Life Safety performance under the BSE-1E seismic hazard level.
**Analysis Method** — Engineers use linear or nonlinear analysis methods depending on building characteristics. Most Santa Monica soft story retrofits use the linear static procedure for Type 1 buildings (wood-frame construction with tuck-under parking).
**Foundation Evaluation** — Existing foundations must be evaluated for the increased loads introduced by the retrofit. Santa Monica requires foundation engineering analysis to confirm adequate capacity or design foundation strengthening.
Typical Retrofit Scope for Santa Monica Buildings
A soft story retrofit in Santa Monica typically involves:
- **Steel moment frames** — Installed at ground-floor openings to provide lateral resistance while maintaining parking access
- **Plywood shear walls** — Added to ground-floor walls where existing framing allows
- **Hold-down anchors** — Simpson Strong-Tie HD or equivalent anchors resist overturning forces
- **Foundation upgrades** — New concrete footings beneath moment frame columns transfer lateral loads to the soil
- **Drag struts and collectors** — Transfer lateral forces from upper floors to new ground-floor lateral elements
- **Connection hardware** — Metal connectors tie the retrofit system to existing wood framing
Santa Monica Plan Check Requirements
Santa Monica Building and Safety requires the following for soft story retrofit plan submission:
- Retrofit construction drawings showing all new structural elements
- Connection details for retrofit-to-existing-structure interfaces
- Foundation plans showing new footings and reinforcement
- Shoring and construction sequence plans
- Special inspection requirements and testing protocols
Plan check review in Santa Monica typically takes 4 to 8 weeks for soft story retrofit projects. Incomplete submissions or submissions requiring significant corrections extend this timeline.
Soft Story Retrofit Cost in Santa Monica
Engineering Fees
Structural engineering for a soft story retrofit in Santa Monica costs $3,500 to $8,000 depending on building size and complexity. This fee includes:
- Structural analysis and design calculations
- Construction drawings (typically 5 to 12 sheets)
- Plan check response and corrections
- Construction observation during retrofit installation
AAA Engineering & Design provides competitive engineering fees for Santa Monica soft story retrofits with transparent pricing and no hidden costs.
Construction Costs
Soft story retrofit construction in Santa Monica ranges from $60,000 to $200,000+ depending on:
| Building Size | Typical Construction Cost | Cost Per Unit | |---------------|--------------------------|---------------| | 3–8 units | $60,000–$100,000 | $8,000–$15,000 | | 9–15 units | $80,000–$150,000 | $7,000–$12,000 | | 16+ units | $120,000–$200,000+ | $6,000–$10,000 |
Per-unit costs decrease for larger buildings because fixed costs (mobilization, steel fabrication, foundation work) spread across more units. Santa Monica contractors experienced with soft story retrofits complete most projects in 8 to 16 weeks.
Cost Recovery Options for Santa Monica Building Owners
Santa Monica's rent control ordinance includes provisions for retrofit cost recovery through capital improvement rent increases. Building owners can petition the Santa Monica Rent Control Board for:
- **Seismic retrofit surcharge** — Specific provisions for seismic upgrade cost recovery
The Rent Control Board reviews each petition individually. Documentation of engineering costs, construction costs, and permits strengthens the application. Building owners should consult with their property management attorney regarding the current cost recovery provisions available in Santa Monica.
Penalties for Non-Compliance in Santa Monica
Financial Penalties
Santa Monica enforces soft story retrofit compliance through escalating penalties:
- **Daily fines** — Starting at $500 per day for continued non-compliance
- **Administrative citations** — Additional penalties layered on top of daily fines
- **Lien on property** — Accumulated fines recorded as a lien against the property in Santa Monica
Operational Consequences
Beyond financial penalties, non-compliant soft story buildings in Santa Monica face:
- **Insurance complications** — Carriers increasingly require seismic retrofit documentation for policy renewal
- **Sale impediments** — Buyers and lenders identify non-compliant buildings during due diligence, reducing property value or blocking transactions
- **Tenant liability** — Building owners bear enhanced liability for tenant injuries during an earthquake if the building was identified as requiring retrofit and the owner failed to comply
The Soft Story Retrofit Engineering Process
Phase 1: Building Evaluation
The engineering process for a Santa Monica soft story retrofit begins with a thorough evaluation of the existing building.
**Field Investigation** — Your structural engineer visits the Santa Monica property to document:
- Existing structural framing (floor joists, wall studs, headers, posts)
- Foundation type and condition
- Ground-floor wall layout and opening locations
- Upper-floor framing and lateral system
- Building dimensions and floor-to-floor heights
**Document Review** — The engineer reviews available building plans, soils reports, and previous engineering assessments. For older Santa Monica buildings, original plans may not exist, requiring more extensive field investigation.
**Structural Inspection** — A thorough inspection identifies existing deficiencies beyond the soft story condition, including deteriorated framing, inadequate connections, and foundation problems that must be addressed during the retrofit.
Phase 2: Structural Analysis and Design
**Demand Analysis** — The engineer calculates seismic forces on the Santa Monica building using site-specific seismic hazard data, soil classification, and building dynamic characteristics.
**Capacity Evaluation** — Existing structural elements are evaluated against seismic demands. The analysis identifies specific deficiencies: inadequate shear capacity, insufficient overturning resistance, weak diaphragm connections, and foundation shortcomings.
**Retrofit Design** — The engineer designs new structural elements to address identified deficiencies. For Santa Monica soft story buildings, this typically means steel moment frames at parking openings, supplemental shear walls, and foundation upgrades.
**Cost Optimization** — An experienced structural engineer minimizes retrofit construction cost while meeting all code requirements. Frame locations, sizes, and connection details directly affect construction cost. AAA Engineering & Design optimizes every Santa Monica soft story retrofit design for cost-effectiveness.
Phase 3: Plan Preparation and Permitting
**Construction Documents** — The engineer prepares detailed structural drawings and specifications for the Santa Monica Building and Safety Department. Plans include:
- Retrofit framing plans
- Foundation plans
- Structural details and sections
- Connection schedules
- Special inspection requirements
- General and structural notes
**Plan Submission** — Complete plans with stamped calculations are submitted to Santa Monica for review. Your structural engineer coordinates with the plan checker to resolve any comments efficiently.
**Permit Issuance** — Once Santa Monica Building and Safety approves the plans, a building permit is issued. Construction can begin immediately upon permit issuance.
Phase 4: Construction Support
**Pre-Construction Meeting** — The structural engineer reviews retrofit plans with the contractor to clarify construction sequence, critical connections, and quality requirements for the Santa Monica project.
**Construction Observation** — During construction, the engineer conducts periodic site visits to verify the contractor installs retrofit elements according to the plans. Critical observations include:
- Steel moment frame erection and connection welding
- Hold-down anchor installation
- Foundation reinforcement and concrete placement
- Shear wall nailing and anchorage
- Drag strut and collector installation
**Special Inspections** — Santa Monica requires special inspections for structural steel welding, high-strength bolting, and concrete placement. The structural engineer specifies inspection requirements and reviews inspection reports.
Common Soft Story Retrofit Challenges in Santa Monica
Parking Access Preservation
Building owners in Santa Monica need to maintain parking functionality during and after the retrofit. Steel moment frames are designed to span parking stall openings without reducing the number of available spaces. Frame column locations must coordinate with parking layout geometry.
Tenant Coordination
Santa Monica's strong tenant protections require careful coordination during retrofit construction. Building owners must provide adequate notice to tenants, maintain habitable conditions during construction, and minimize disruption. Construction typically occurs at ground level, but noise, dust, and access restrictions affect upper-floor tenants.
Utility Conflicts
Ground-floor utilities — gas lines, water mains, electrical panels, and sewer laterals — often conflict with new foundation elements and steel columns. The retrofit engineer coordinates with utility providers to relocate conflicting services in Santa Monica properties.
Historic Building Considerations
Santa Monica has numerous historic properties subject to the soft story retrofit requirement. Historic buildings require retrofit designs that preserve character-defining features while achieving seismic performance objectives. The Santa Monica Landmarks Commission reviews retrofit plans for designated historic structures.
Why Choose AAA Engineering & Design for Santa Monica Soft Story Retrofits
**Licensed Professional Engineers** — Every Santa Monica soft story retrofit project is designed and stamped by California-licensed Professional Engineers with specific expertise in seismic retrofitting.
**20+ Years of Experience** — Our team has designed soft story retrofits throughout Southern California, including numerous projects in Santa Monica and surrounding Westside communities.
**Cost-Effective Designs** — We optimize retrofit designs to minimize construction cost while exceeding code requirements. Our Santa Monica clients consistently report lower construction bids compared to projects designed by competitors.
**Fast Turnaround** — We understand the urgency of Santa Monica's soft story retrofit deadlines. Our typical turnaround for retrofit engineering plans is 14 to 21 business days.
**Full-Service Support** — From initial evaluation through construction completion, AAA Engineering & Design supports your Santa Monica soft story retrofit project at every stage.
Take Action on Your Santa Monica Soft Story Retrofit
Every day of non-compliance with Santa Monica's soft story retrofit requirements costs building owners money in potential fines and increases earthquake risk for tenants. The engineering and permitting process takes 2 to 4 months, and construction adds another 2 to 4 months. Starting now ensures compliance before penalties escalate.
**Call AAA Engineering & Design at (949) 981-4448** for a free evaluation of your Santa Monica soft story building. We provide a detailed scope of work, transparent pricing, and a timeline for achieving full compliance with Santa Monica's seismic retrofit requirements.
Frequently Asked Questions
What is the soft story retrofit deadline in Santa Monica? Santa Monica established phased compliance deadlines based on building size. Buildings with 16+ units faced the earliest deadlines, followed by 3-15 unit buildings. All affected building owners have received notification. Contact Santa Monica Building and Safety or call AAA Engineering at (949) 981-4448 to determine your specific deadline.
How much does a soft story retrofit cost in Santa Monica? A complete soft story retrofit in Santa Monica costs $60,000 to $200,000+ for construction, plus $3,500 to $8,000 for structural engineering. Per-unit costs range from $6,000 to $15,000 depending on building size. Larger buildings achieve lower per-unit costs due to economies of scale.
Can I pass soft story retrofit costs to tenants in Santa Monica? Santa Monica's rent control ordinance allows building owners to petition the Rent Control Board for capital improvement surcharges that pass a portion of retrofit costs to tenants over a defined period. Each petition is reviewed individually based on documented costs and building circumstances.
How long does a soft story retrofit take in Santa Monica? The complete process from initial engineering evaluation to construction completion takes 4 to 8 months for most Santa Monica soft story buildings. Engineering and permitting require 2 to 4 months, and construction takes 2 to 4 months depending on building size and retrofit complexity.
Do I need a structural engineer for a soft story retrofit in Santa Monica? Yes. Santa Monica requires stamped structural calculations and construction drawings from a California-licensed Professional Engineer (PE) or Structural Engineer (SE) for all soft story retrofits. The engineer designs the retrofit system, prepares permit documents, and provides construction observation.
What happens if my Santa Monica building fails the soft story screening? Buildings that fail Santa Monica's soft story screening are placed on the mandatory retrofit list. Building owners receive a Notice of Non-Compliance with specific deadlines for submitting retrofit plans and completing construction. Failure to respond triggers escalating fines starting at $500 per day.
Can I sell a building that needs a soft story retrofit in Santa Monica? You can sell a Santa Monica building that requires a soft story retrofit, but the retrofit obligation transfers to the new owner. Buyers factor the retrofit cost into their purchase price, typically reducing the property's market value by the estimated retrofit expense. Completing the retrofit before sale maximizes property value.
What type of engineer do I need for a Santa Monica soft story retrofit? You need a California-licensed Professional Engineer (PE) with structural engineering expertise or a licensed Structural Engineer (SE). The engineer must have experience with ASCE 41-17 seismic evaluation standards and wood-frame soft story retrofit design. AAA Engineering & Design specializes in [seismic retrofitting](/services/seismic-retrofitting) for Santa Monica and all of Southern California.
What are the daily fines for missing the Santa Monica soft story retrofit deadline? Santa Monica imposes fines starting at $500 per day for continued non-compliance after the deadline. Administrative citations are layered on top of daily fines, and accumulated amounts become a lien on the property. Building owners who act now avoid fines that can reach tens of thousands of dollars within months.
How much does soft story retrofit engineering cost in Santa Monica in 2026? Structural engineering for a Santa Monica soft story retrofit costs $3,500 to $8,000 in 2026 depending on building size and complexity. This includes building evaluation, structural analysis, construction drawings (5–12 sheets), plan check response, and construction observation. AAA Engineering provides transparent, fixed-fee proposals.
What is the Santa Monica soft story retrofit compliance checklist for 2026? The compliance checklist includes: (1) confirm your building meets the ordinance criteria (wood-frame, 3+ stories or 2+ stories with ground-floor parking, built before 1978); (2) hire a California-licensed PE; (3) complete structural screening report; (4) submit PE-stamped retrofit plans to Santa Monica Building and Safety; (5) obtain building permit; (6) complete construction and pass final inspection. Call (949) 981-4448 to start today.
---
*Updated February 22, 2026. Santa Monica soft story retrofit requirements and deadlines are subject to change by city ordinance. Contact AAA Engineering & Design at (949) 981-4448 for current compliance information and engineering services.*
```json { "@context": "https://schema.org", "@graph": [ { "@type": "Organization", "name": "AAA Engineering & Design", "telephone": "(949) 981-4448", "url": "https://aaaengineeringdesign.com" }, { "@type": "LocalBusiness", "name": "AAA Engineering & Design", "telephone": "(949) 981-4448", "areaServed": "Santa Monica, California" }, { "@type": "Article", "headline": "Soft Story Retrofit Deadline in Santa Monica: 2026 Compliance Guide", "datePublished": "2026-02-21", "dateModified": "2026-02-21", "author": { "@type": "Organization", "name": "AAA Engineering & Design" } }, { "@type": "FAQPage", "mainEntity": [ { "@type": "Question", "name": "What is the soft story retrofit deadline in Santa Monica?", "acceptedAnswer": { "@type": "Answer", "text": "Santa Monica established phased compliance deadlines based on building size. All affected building owners have received notification. Contact Santa Monica Building and Safety to determine your specific deadline." } }, { "@type": "Question", "name": "How much does a soft story retrofit cost in Santa Monica?", "acceptedAnswer": { "@type": "Answer", "text": "A complete soft story retrofit in Santa Monica costs $60,000 to $200,000+ for construction, plus $3,500 to $8,000 for structural engineering." } }, { "@type": "Question", "name": "Can I pass soft story retrofit costs to tenants in Santa Monica?", "acceptedAnswer": { "@type": "Answer", "text": "Santa Monica's rent control ordinance allows building owners to petition the Rent Control Board for capital improvement surcharges that pass a portion of retrofit costs to tenants." } }, { "@type": "Question", "name": "How long does a soft story retrofit take in Santa Monica?", "acceptedAnswer": { "@type": "Answer", "text": "The complete process from initial engineering evaluation to construction completion takes 4 to 8 months for most Santa Monica soft story buildings." } }, { "@type": "Question", "name": "Do I need a structural engineer for a soft story retrofit in Santa Monica?", "acceptedAnswer": { "@type": "Answer", "text": "Yes. Santa Monica requires stamped structural calculations and construction drawings from a California-licensed Professional Engineer (PE) or Structural Engineer (SE) for all soft story retrofits." } }, { "@type": "Question", "name": "What happens if my Santa Monica building fails the soft story screening?", "acceptedAnswer": { "@type": "Answer", "text": "Buildings that fail screening are placed on the mandatory retrofit list with specific deadlines. Failure to respond triggers escalating fines starting at $500 per day." } }, { "@type": "Question", "name": "Can I sell a building that needs a soft story retrofit in Santa Monica?", "acceptedAnswer": { "@type": "Answer", "text": "You can sell the building, but the retrofit obligation transfers to the new owner. Buyers factor the retrofit cost into their purchase price." } }, { "@type": "Question", "name": "What type of engineer do I need for a Santa Monica soft story retrofit?", "acceptedAnswer": { "@type": "Answer", "text": "You need a California-licensed Professional Engineer (PE) with structural engineering expertise or a licensed Structural Engineer (SE) experienced with ASCE 41-17 standards." } } ] }, { "@type": "Service", "name": "Soft Story Retrofit Engineering", "provider": { "@type": "Organization", "name": "AAA Engineering & Design" }, "areaServed": "Santa Monica, California", "description": "Licensed PE structural engineering for soft story seismic retrofits in Santa Monica, including evaluation, design, permitting, and construction observation." } ] } ```